Mecer 1.2kVA 720W 12V inverter

Mecer
Availability:

In stock


SKU: IVR-1200LBKS

Quick Specs:

  • 1.2kVA 720W 12V Inverter
  • Requires 1x 100Ah 12V Deep Cycle Battery (excluded)
  • Weight: 4.5kg
  • Dimensions: 350 x 90 x 300

 

R2 299.00

In stock

wws Need Help? Contact Us via WhatsApp
Please note: Images are for illustrative purposes only.

Overview & Features

Tackle loadshedding with the Mecer 1.2kVA 720W 12V Inverter.  Includes three SA socket outlets for your TV, DSTV, DVD player, Laptop, ADSL/Fibre router.

It is recommended that the inverter NOT be used to power any heating elements (kettle, microwave) as this will place excessive load on the battery and thereby shorten the life span of the battery.

Features:

  • Simulated sine wave inverter
  • Built-in AVR for voltage regulation
  • Wide input voltage range: 90-280 VAC
  • Overload and short circuit protection
  • LCD display for comprehensive information

The table below indicates the typical performance of the Mecer 1.2kVA 720W 12V Inverter with  1x 100Ah 12V deep cycle battery (excluded):

  • Estimated Recharge Time: 7 hours
  • Dimension, D X W X H (mm) 350 x 90 x 300
  • Net Weight 4.5kg

Approximate Back-up Time Table for 1x 100Ah Batteries

***The below table is a rough estimate only, and does not guarantee any run-down times offered! Please do not consider these times as fact. Due to the nature of these technologies, including but not limited to the type and quality of batteries used, power draw from connected devices, load fluctuation, etc. no fully accurate times can be offered.

Downloads:

Datasheet

SKU: IVR-1200LBKS Categories: , ,
MODEL Mecer IVR-1200LBK
CAPACITY  1.2KVA/ 720W
Power Factor 0.6
Intput voltage range 90-280VAC
LINE MODE
Output voltage Bypass mode: 0utput voltage same as input voltage
AVR mode:Output voltage = Input voltage*1.2 @ Input voltage<200VAC
Output Frequency Same as input
BATTERY MODE
Output voltage 230Vac ±10%
Transfer Time  20ms typical
Waveform Modified Sine-wave
OVERLOAD CAPABILITY
Bypass Mode (in VA and Watts) Load >110%±15% , alarm 5 mins then fault
Load >130% ±15%, fault immediately.
AVR Mode
(in VA and Watts)@ Input voltage > 170VAC
Load >100%±15%, go to bypass mode
AVR Mode
(in VA and Watts)@ Input voltage < 170VAC
 Load >60%±15%, go to bypass mode
Battery Mode (in W) Load>110% ±15%, overload alarm for 15s, and then will switch to fault mode for 10s.
Then unit will re-start for 5 times.
Load>120% ±15% , fault & cut off O/P immediately.
SHORT CIRCUIT PROTECTION
Line Mode  Breaker
Battery Mode  Current limit +Firmware Protection
BATTERY
Battery Voltage  12VDC
Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
Polarity Reserve Protection  Yes
Charger available I/P range 90~280V
CHARGER
Constant Current Charger Voltage 14.3VDC ±2%
Floating Charge Voltage  13.7VDC ±2%
Maximum Charge Current  10A or 20A
DC Start Voltage  >11VDC
PHYSICAL
Dimension, D X W X H (mm)  350 x 90 x 300
Net Weight (kgs) 4.5
ENVIRONMENT
Operating Temperature 0℃ to 40℃
Storage Temperature -15℃ to 50℃
Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
Product specifications are subject to change without further notice