Quick Specs:

  • 2.4kVA 1.44kW DC-AC Inverter
  • Requires 2x 100Ah 12V Deep Cycle Batteries (excluded)
  • Weight: 5.5kg
  • Dimensions:350 x 90 x 300

R2 059.00

Out of stock

Spread the word

Overview & Features

Tackle loadshedding with the Mecer 2.4kVA 1.44kW 24V Inverter.  Includes three SA socket outlets for your TV, DSTV, DVD player, Laptop, ADSL/Fibre router.

It is recommended that the inverter NOT be used to power any heating elements (kettle, microwave) as this will place excessive load on the battery and thereby shorten the life span of the battery.

Features:

  • Simulated sine wave inverter
  • Built-in AVR for voltage regulation
  • Wide input voltage range: 90-280 VAC
  • Overload and short circuit protection
  • LCD display for comprehensive information

The table below indicates the typical performance of the Mecer 2.4kVA 1.44kW 24V Inverter with  2x 100Ah 12V deep cycle batteries (excluded):

  • Estimated Recharge Time: 7 hours
  • Dimension, D X W X H (mm) 350 x 90 x 300
  • Net Weight 5.5kg

Approximate Back-up Time Table for 2x 100Ah Batteries

***The below table is a rough estimate only, and does not guarantee any run-down times offered! Please do not consider these times as fact. Due to the nature of these technologies, including but not limited to the type and quality of batteries used, power draw from connected devices, load fluctuation, etc. no fully accurate times can be offered.

Downloads:

Datasheet

SKU: IVR-2400LBKS Categories: ,
Spread the word
MODEL Mecer IVR-2400LBK
CAPACITY2.4KVA/1440W
Power Factor0.6
Intput voltage range90-280VAC
LINE MODE
Output voltageBypass mode: 0utput voltage same as input voltage
AVR mode:Output voltage = Input voltage*1.2 @ Input voltage<200VAC
Output FrequencySame as input
BATTERY MODE
Output voltage230Vac ±10%
Transfer Time 20ms typical
WaveformModified Sine-wave
OVERLOAD CAPABILITY
Bypass Mode (in VA and Watts)Load >110%±15% , alarm 5 mins then fault
Load >130% ±15%, fault immediately.
AVR Mode
(in VA and Watts)@ Input voltage > 170VAC
Load >100%±15%, go to bypass mode
AVR Mode
(in VA and Watts)@ Input voltage < 170VAC
 Load >60%±15%, go to bypass mode
Battery Mode (in W)Load>110% ±15%, overload alarm for 15s, and then will switch to fault mode for 10s.
Then unit will re-start for 5 times.
Load>120% ±15% , fault & cut off O/P immediately.
SHORT CIRCUIT PROTECTION
Line Mode Breaker
Battery Mode Current limit +Firmware Protection
BATTERY
Battery Voltage24VDC
Acceptable Battery TypeRechargeable lead-acid battery, Deep discharge battery
Polarity Reserve Protection Yes
Charger available I/P range90~280V
CHARGER
Constant Current Charger Voltage 28.6VDC ±2%
Floating Charge Voltage 27.4VDC ±2%
Maximum Charge Current 10A or 20A
DC Start Voltage >22VDC
PHYSICAL
Dimension, D X W X H (mm) 350 x 90 x 300
Net Weight (kgs)5.5
ENVIRONMENT
Operating Temperature0℃ to 40℃
Storage Temperature-15℃ to 50℃
Operating Humidity0 to 90% Relative Humidity(Non-condensing)
Product specifications are subject to change without further notice

Based on 2 reviews

5.0 overall
2
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

  1. Rakshini (verified owner)

    Verified reviewVerified review - view originalExternal link

    Rakshini

  2. Rakshini (verified owner)

    Verified reviewVerified review - view originalExternal link

    Rakshini